Exposed linear encoder with singlefield scanning
Home > Products > Length Measurement > Exposed Linear Encoders > MS 14
MS 14 |Overview
- Small dimensions
- System resolution: 10 µm – 0.05 µm
- Display of the signal quality directly at the scanning head via 3-coloured LED function
- Easy mounting without additional test box
- Easy mounting as a result of large mounting tolerances
- High insensitivity to contamination by use of an extensive singlefield scanning principle
- Interface: TTL, sinus 1 Vpp
- High permissible traversing speed
- Reference mark (accurate and repeatable from both traversing directions)
Position selectable by customer - Integrated subdividing electronics in the encoder head: for up to times 200 interpolation (before quadrature)
- Max. measuring length: 10 000 mm
Distribution Austria
RSF Elektronik Ges.m.b.H
MS 14 |Scanning head
Model | AK MS 14 1 Vpp | AK MS 14 TTLx1u | AK MS 14 TTLx5 | AK MS 14 TTLx10 | AK MS 14 TTLx20 | AK MS 14 TTLx25 | AK MS 14 TTLx50 | AK MS 14 TTLx100 | AK MS 14 TTLx200 |
Interface | ∿ 1 Vpp | TTL | TTL | TTL | TTL | TTL | TTL | TTL | TTL |
Measuring step [µm] | Depending on external interpolation | 10.00 | 2.00 | 1.00 | 0.50 | 0.40 | 0.20 | 0.10 | 0.05 |
Integrated interpolation | -- | Times 1 | Times 5 | Times 10 | Times 20 | Times 25 | Times 50 | Times 100 | Times 200 |
Max. output frequency [kHz] | 250 | -- | -- | -- | -- | -- | -- | -- | -- |
Velocity typ. [m/s] Edge separation amin [ns] | 10.00 -- | 10.00 500 | 6.40 300 | 3.20 300 | 2.40 200 | 1.92 200 | 1.92 100 | 0.96 100 | 0.96 50 |
Velocity max. [m/s] Edge separation amin [ns] | 10.00 -- | 10.00 500 | 9.60 200 | 9.60 100 | 9.60 50 | 9.60 40 | 4.80 40 | 2.40 40 | 1.20 40 |
Further features of the scanning head | |
Interpolation error | Typical ±65 nm (Peak-Peak) |
Electrical connection | Cable, 0.5 m, 1 m or 3 m with D-sub connector, male, 15-pin |
Voltage supply | +5 V ±10 % |
Power consumption | Max. 770 mW (without load) |
Current consumption | Max. 140 mA (without load) |
Vibration 55 Hz – 2000 Hz | ≤ 150 m/s² (EN 60 068-2-6) |
Shock 8 ms | ≤ 750 m/s² (EN 60 068-2-27) |
Operating temperature | 0 °C to 50 °C |
Storage temperature | −20 °C to 70 °C |
Mass | Scanning head: 14 g (without cable), cable: 30 g/m, connector: D-sub connector: 28 g |
MS 14 |Graduation carrier
MS 14 version MK – Steel tape scale with adhesive tape
Grating carrier with adhesive tape
MS 14 Version MP – Steel tape scale in aluminum carrier with clamping element
Carrier with adhesive tape, clamping element bolted
MS 14 |Accessories
Tape mounting tool TMT Mx 15 MK
Enables a safe and precise mounting of a steel tape scale.
Mounting instructions: TMT Mx 15 MK tape mounting tool or TMT Mx 15 MK-LH tape mounting tool for left handers
PWT 100 / PWT 101
The PWT 100 / PWT 101 is a testing device for checking the function and adjustment of RSF Elektronik encoders. Thanks to its compact dimensions and robust design, the PWT 100 / PWT 101 is ideal for mobile use. A 4.3-inch touchscreen provides for display and operation. For example, for encoders with EnDat interface you can not only display the position value but also export the online diagnosis, shift datums, and perform further inspection functions.
Available functions
The performance range of the PWT 100 / PWT 101 can be expanded by firmware update. Appropriate firmware files that can be imported to the PWT 100 through a memory card (not included in delivery) will be made available at www.heidenhain.de.
MS 14 |Downloads
Catalogues | |
---|---|
MS 14 | 1859.51 KB |
Mounting Instructions | |
---|---|
AK MS 14 | 1723.67 KB |
MS 14 MK | 1480.83 KB |
MS 14 MP | 1595.18 KB |
EC Declaration of conformity | |
---|---|
MS 14-EC declaration of conformity | 569.47 KB |