Product parameters | Product values and -details |
Electrical connection | Cable, 0.5, 1 m or 3 m with D-sub connector, male, 15-pin |
Voltage supply | +5 V ±5 % |
Power consumption max. | 660 mW (without load) |
Current consumption typ. | 120 mA (without load) |
Vibration 40 Hz – 2000 Hz | 150 m/s2 |
Shock 8 ms | 300 m/s2 |
Operating temperature | 0 °C to 50 °C |
Storage temperature | −20 °C to 70 °C |
Mass reading head |
- 171 g (without cable)
- Cable: 30 g/m, connector: D-sub connector: 28 g
|
Standard measuring lengths (ML)[mm] | 70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 620, 720, 770, 820, 920, 1040, 1140, 1240, 1340, 1440, 1540 (other ML on request) |
Graduation carrier | Glass scale (αtherm ≈ 8.5 x 10–6 K–1), Grating period: 200 µm |
Accuracy grades (at 20 °C) | ±10 µm/m |
Location of the reference marks (RI) |
- One reference mark in the center of measuring length or 35 mm from either end of measuring length
- Optional: one reference mark at any location, additional reference marks can be selected by distances of n × 50 mm.
|
Required moving force | < 5.0 N |
Environmental protection EN 60529 | IP 52 |
Mass scale spar (approx.) | 237 g + 1.17 g/mm (ML) |