Product parameters | Product values and -details |
Voltage supply |
- Sinusoidal voltage signals 1 Vpp: +5 V ±10 %
- Square-wave signals via line driver: +5 V ±10 %
|
Power consumption max. |
- Sinusoidal voltage signals 1 Vpp: 825 mW (without load)
- Square-wave signals via line driver: 990 mW (without load)
|
Current consumption typ. |
- Sinusoidal voltage signals 1 Vpp: 150 mA (without load)
- Square-wave signals via line driver: 180 mA (without load)
|
Vibration 55 Hz – 2000 Hz | 100 m/s2 |
Schock 8 ms | 200 m/s2 |
Operating temperature | 0 °C to 50 °C |
Storage temperature | −20 °C to 70 °C |
Mass reading head | 65 g (without cable) |
Standard measuring lengths (ML)[mm] | 70, 120, 170, 220, 270, 320, 370, 420, 470, 520, 570, 620, 670, 720, 770, 820, 870, 920, 970, 1040, 1140, 1240 (other measuring lengths on request) |
Graduation carrier |
- Glass scale (αtherm ≈ 8.5 x 10-6 K-1), Grating period: 20 µm
- Glass ceramic scale (αtherm ≈ 0 x 10-6 K-1), Grating period: 20 µm
|
Accuracy grades (at 20 °C) | |
Location of the reference marks (RI) |
- Distance-coded reference marks
- One reference mark in the middle of the ML
- Up to ML 970 mm: 35 mm from left and right; from ML 1040 mm: 45 mm from left and right
|
Required moving force | With standard sealing lips (NBR): < 2.0 N |
Environmental protection EN 60529 | With standard sealing lips (NBR): IP 53 |
Mass scale spar (approx.) | 75 g + 0.57 g/mm (ML) |