| Product parameters | Product values und -details |
| Weight (approx.) | 17 g/m + 40 g (scanning head with connector) + 30 g/m cable |
| Grating carrier | Steel tape scale |
| Grating period | 40 µm |
| Accuracy grades | ±5 µm/m, ±15 µm/m |
| Non-linearity | ±3 µm/m |
| Max. measuring length | 20 000 mm |
| Reference marks | - Standard 50 mm (equidistant)
- Position selectable by customer
|
| Vibration 55 Hz − 2000 Hz | ≤ 150 m/s² (EN 60 068-2-6) |
| Shock 8 ms | ≤ 750 m/s² (EN 60 068-2-27) |
| Permissible temperature | −20 °C (storage), 0 °C to +60 °C (operation) |
| Standard cable | 0.5 m, 1 m or 3 m cable with sub-D connector 15-pin (male) |
| RoHS-conformity | The linear encoders of MS 15 comply with the guideline of the RoHS-directive 2011/65/EU and also with the delegated directive 2015/863/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment |